0420 119 140More ways to reach us
On-site across Sydney · Remote support Australia-wide
Skip to content
Sydney WiFi & Computer RepairSydney WiFi
The apartment building's basement car park with its metal deck ceiling

Featured case · Parramatta · Building network

Basement car park WiFi: one password per unit

A strata committee found us on Google: two basement levels, a tight budget and one account per unit to keep outsiders off. Our plan uses a wired backbone, per-level mesh and PPSK

Location
Parramatta NSW 2150
Client
Strata committee
Found us via
Google → email
Area
Basement car park B2, B3
Equipment
UniFi · U6-Mesh
Stage
Plan submitted
RESULTAfter a site visit we prepared several options, and the committee is now deciding. The plan: a vertical wired backbone with mesh on each level, and PPSK so each unit has its own password that phones and cars enter once.

THE CLIENT

Two basement levels that need WiFi, without freeloaders

The client is the strata committee of a large mixed-use apartment building in Parramatta. They searched on Google, found us near the top of the results and emailed the address on our website.

We replied promptly, booked a time and walked the site with committee members and the building manager. The brief: on a tightly controlled budget, give basement levels B2 and B3 basic WiFi coverage for residents' phones and cars, with one account per unit.

EmailFound us on Google
Site visitWith the committee and building manager
OptionsSeveral plans to decide on
NowPlan submitted, committee deciding
01
First contact
A Google search, then an email

The first email was short: a strata scheme for a building in Parramatta wanted WiFi in two basement car park levels, and asked whether we could help.

The strata committee's first email asking about WiFi in two basement car park levels (sender and dates hidden)
The first email: WiFi for two basement levels
The client's reply: WiFi for residents and visitors, and a request for a site visit (sender and dates hidden)
The reply: for residents and visitors, please visit
  1. 1

    Prompt reply

    We answered quickly and confirmed what the WiFi was for and where.

  2. 2

    Site visit

    At the agreed time we walked the areas to be covered with committee members and the building manager.

  3. 3

    Several options

    After the visit we prepared more than one version of the plan for the committee to discuss and choose from. The plan is with the committee now.

02
Four challenges
From the site visit and the committee's brief

The car park is large, the ceiling is metal decking, and thick reinforced concrete separates the levels.

  1. 1

    The building and the works

    Hard-wiring the whole car park the traditional way would take a long time, disturb residents and cost far more in conduit and cable than the committee's budget.

  2. 2

    A separate network

    For security and bandwidth reasons, building management would not allow the car park WiFi to share the existing common network. It had to be physically separate.

  3. 3

    One account per unit

    The committee ruled out a single shared WiFi password. Each unit needed its own account, with at most 5 devices online at once, to keep outsiders off.

  4. 4

    Cars and smart devices

    The usual captive portal login page doesn't appear on cars such as Teslas that lack a full browser, and asking older residents to find and submit device MAC addresses isn't realistic.

The metal deck ceiling and services in the basement car park
The car park's metal deck ceiling
Existing conduit runs on the car park ceiling
Existing conduit on the ceiling
Part of the basement car park at the site visit (number plates hidden)
The car park at the site visit (plates hidden)
An aisle and columns in the basement car park (number plates hidden)
Aisle and columns
A long aisle in the basement car park (number plates hidden)
The length of one level
03
The network
Wired backbone, mesh within each level

We ruled out home mesh routers and the expensive fully cabled approach, and planned a hybrid: wired vertically, wireless across each level.

  1. 1

    Separate service and vertical backbone

    We help the committee order a new, separate business FTTB service. To avoid the heavy signal loss through concrete slabs, cable runs vertically from the ground-floor MDF, with fire stopping, straight down to B2 and B3, giving each level a wired root node.

  2. 2

    Hybrid mesh on each level

    B2 and B3 would each use UniFi business equipment: a wired main access point, extended across the level by IPX5-rated U6-Mesh access points with clear line of sight under the metal ceiling.

  3. 3

    Four nodes per level

    In the plan, four nodes cover each level, avoiding large amounts of drilling and conduit.

The building's main distribution frame
The building's main distribution frame, photographed at the site visit
Existing pipe penetrations through the slab
Checking where cable can pass between levels
A penetration beside the ductwork
A wall penetration
04
One password per unit
PPSK, so cars connect directly

To handle cars that can't show a login page and residents who can't look up MAC addresses, the plan enables PPSK (Private Pre-Shared Key) on the UniFi cloud gateway.

  1. 1

    One WiFi name

    A single network name across the whole car park.

  2. 2

    A password for each unit

    Every unit gets its own unique password.

  3. 3

    Enter it once

    Residents type it in once, as they would at home, and their phone and car connect automatically from then on.

  4. 4

    Five devices per unit

    The system caps each password at 5 devices online at once: simple to join, strict to manage.

05
Expected outcomes
Cost, works and ongoing management

Wired vertically and wireless across each level, the design cuts cost and construction without giving up stability.

  1. 1

    Cost

    An estimated saving of close to 50% against traditional full cabling.

  2. 2

    Works

    The physical install in the car park is planned for half a day, with minimal disturbance to residents.

  3. 3

    Management

    Once live, the committee only needs to issue or disable a unit's password in the controller.

What the plan covers: the provider order, compliant cabling works and the security setup, delivered as one job.

THE PLAN
WiFi for two car park levels, one password per unit.

A separate service, a wired vertical backbone and four nodes per level. Each unit has its own password for up to 5 devices, entered once on phones and cars.

Next step

WiFi for your building's car park or common areas?

Email us about the building. We'll visit the site first, then give the committee options to choose from.

Building network · Car park WiFi · UniFi